Count Controlled Tester
Operating Instructions
Legend for instruction sheet picture.
- Universal Platen Specimen Holder
- Universal Vise Specimen Holder
- Lighted Magnifier
- Compensating Wind Up Reel
- Level on base plate, used to level machine
- Sliding Gauge Pin, used in setting indicator 'Z' which should be
matched with "O" ring when paper rests on test area and
sliding pin gauge is withdrawn from under rocker arm "H".
- Cycle Counter
- Rocker Arm
- Cam Follower Shaft Screw
- Vertical Shaft Fine Adjustment Screw
- Vertical Shaft, location is adjustable
- Machine Cover
- Clamping Screw on rocker arm, used to change angle of vertical
shaft if desired to get comparable test readings
at extreme elevations.
- Frame with Nylon Bearings, used to guide paper or tape without
making any adjustments.
- "O" Ring, which must not be used if worn flat or over 6 months old.
- Box Anvil, used to secure parallel specimens.
- Aluminum Feed Off Reel with 11/16" wide abrasion paper (Federal Spec. # UUT00126E)
- Two Counter Weights, to mount at rear of rocker arm to reduce total
load on specimen to either 55 or 175 Gram load, used in testing "hot Stamped
bright foils". (not shown)
- Count Controller
- 1/4" wide abrasion wear paper, used in testing a concave area and thin line lettering.
- Reserved
- Wrench Set
- Pressure Roller
- Drive Roller
- 1/8" Shim Plate. (Included in accessories box)
- Surface Gauge, for indicating items parallel to base of machine.