Count Controlled Tester
Operating Instructions

Legend for instruction sheet picture.

  1. Universal Platen Specimen Holder
  2. Universal Vise Specimen Holder
  3. Lighted Magnifier
  4. Compensating Wind Up Reel
  5. Level on base plate, used to level machine
  6. Sliding Gauge Pin, used in setting indicator 'Z' which should be matched with "O" ring when paper rests on test area and sliding pin gauge is withdrawn from under rocker arm "H".
  7. Cycle Counter
  8. Rocker Arm
  9. Cam Follower Shaft Screw
  10. Vertical Shaft Fine Adjustment Screw
  11. Vertical Shaft, location is adjustable
  12. Machine Cover
  13. Clamping Screw on rocker arm, used to change angle of vertical shaft if desired to get comparable test readings at extreme elevations.
  14. Frame with Nylon Bearings, used to guide paper or tape without making any adjustments.
  15. "O" Ring, which must not be used if worn flat or over 6 months old.
  16. Box Anvil, used to secure parallel specimens.
  17. Aluminum Feed Off Reel with 11/16" wide abrasion paper (Federal Spec. # UUT00126E)
  18. Two Counter Weights, to mount at rear of rocker arm to reduce total load on specimen to either 55 or 175 Gram load, used in testing "hot Stamped bright foils". (not shown)
  19. Count Controller
  20. 1/4" wide abrasion wear paper, used in testing a concave area and thin line lettering.
  21. Reserved
  22. Wrench Set
  23. Pressure Roller
  24. Drive Roller
  25. 1/8" Shim Plate. (Included in accessories box)
  26. Surface Gauge, for indicating items parallel to base of machine.